Fully overhauled: Mechanics, geometry, hydraulics and electrical parts checked and/or replaced.
Grinding headstock
Disassembly, cleaning of parts, replacement of worn and defective parts, overhaul of motor, replacement of bearings, replacement of belts, disassembly of spindle, replacement of seals and O-Rings + adjustment. New paintwork.
Headstock
Dismantle, clean parts, replace worn and faulty parts, overhaul motor, replace belts. New spindle bearings. New paintwork.
Tailstock
Dismantled, checked and overhauled.
Hydraulics
Dismantle, check motor, replace hoses, defective and worn parts. Check hydraulic block
X-axis
Dismantle, replace worn parts such as O-Rings, seals, rings etc., overhaul hydraulic piston, grind tables.
Z axis
Dismantle, grind tables, replace worn and defective parts, overhaul hydraulic piston, new paintwork.
Electrical cabinet
Complete check, change various relays.
Painting
Colors: White RAL 9003 and gray RAL 7011
Geometry according to manufacturer's protocol.
Inspection and cleaning of various accessories
Manufacturing origin Swiss
Netweight 4000 kg
Custom position 8460.2320
TECHNICAL DATA
(standard)
Distance between centers 650 mm
Centers height 175 mm
Max. workpiece weight 80 kg
Longitudinal slide Z
Max. travel 1000 – 1150 mm
Speed 0.001 to 10’000 mm/min
(mod.beg.years2000 : 0.001-5’000 min-1)
Resolution 0.0001 mm
Cross slide X
Max. travel : 285 mm
Speed 0.001 to 20’000 mm/min
(mod.beg.years2000 : 0.001-10’000 min-1)
Resolution 0.0001 mm
Wheel headstock (universal variant)
Pivoting -15 to 225°
(mod.beg.years2000 : -15 to 195°)
Pivoting axis 2.5 / 1 ° Hirth
Drive power : 7.5 or 9 kW or 11 kW
Wheel 500×63 (80/110F5) x203 mm
Workpiece headstock
Speed 1 – 1500 min-1
Fitting taper MT4 or MT5 / ISO 50
Drive power : 1.6 or 3.0 kW or 4.0 kW
Tailstock
Fitting taper MT3 or MT4
Barrel travel 35 / 50 mm mm
(mod.beg.years2000 : 35 mm.)
Barrel diameter : Ø 50 mm
Smooth setting +/- 40 µ
Control : Fanuc Oi-TD Standalone Panel i
(mod.beg.years2000 : Fanuc 21i-TB
errors and omissions excepted-data given without obligation